◇JCCRM 321 : Evaluate the accuracy of TCa, TMg, Na, k, CL, IP measurements
◇JCCRM 322 : Evaluate the accuracy of Serum Iron measurement
◇JCCRM 324 : Certified Reference Material for Measurement of Inorganic Phosphorus
◇JCCRM 621 : Evaluate the accuracy of blood gas (pH, pCO2, pO2)
◇JCCRM 111 : Evaluate the accuracy of serum Na, K and Cl by ISE measurement
◇JCCRM 300 : Evaluate the accuracy of Dialysate (pH, pCO2, HCO3-, Na, K, Cl) measurement
◇JCTCM 130 : Trueness control material for ISE measuring Na, K, Cl ( 3 levels )
◇JCTCM 131 : Trueness control material for ISE measuring Na, K, Cl ( 1 level )
-
- Certified Reference Material for Measurement of Electrolytes in Human SerumJCCRM 321 (CA)
TCa, TMg, Na, K, Cl, IP
- ¥29,000
-
- Specification
- ・Secondary reference material for Na, K, Cl, TCa&TMg, IP
・Concentration of TCa&TMg were assayed by using atomic absorption spectrophotometry, Na and K were used flame photometry,Cl was used coulometric titration method, IP was used Ion chromatography
・Intended to be used for the calibration of routine ISE(Ion Selective Electrode) analyzers measuring Na, K, and Cl in blood serum(blood plasma) using ISE(diluted or undiluted) in clinical testing
- Contents/Configuration
- ・frozen liquid
・6 vials, 2 vials for each of 3 levels(L,M,H), each vial contains 1.0 mL,
- Expiration date
- ・temperature below -60℃
・shelf life: 6 months after the date of the receipt (-20℃/1 month)
- Certificate of Analysis
-
- Certified Reference Material for Measurement of Serum IronJCCRM 322 (FE)
Fe
- ¥28,000
-
- Specification
- ・Intended to be used for evaluating the accuracy of procedures and calibrating procedures for determination of serum iron
- Contents/Configuration
- ・frozen liquid
・4 vials, 2 vials for each of 2 levels (L, M), each vial contains 1.0 mL
- Expiration date
- ・temperature below -70℃
・shelf life: 9 months after the date of the receipt (-20℃/1 month)
- Certificate of Analysis
-
- Certified Reference Material for Measurement of Inorganic PhosphorusJCCRM 324 (S-IP)
- ¥25,000
-
- Specification
- Intended for use in calibrating and evaluating the accuracy of routine methods and validating working reference materials
- Contents/Configuration
- Frozen liquid
- Expiration date
- Shelf life i: 12 months from the shipping date(-20℃/month)
- Certificate of Analysis
-
- Certified Reference Material for Measurement of Blood GasesJCCRM 621 (BG3-6)
pH, pCO2, pO2
- ¥36,000
-
- Specification
- ・Intended to be used for verifying the accuracy of blood gas (pH, pCO2, pO2) analysers in clinical testing, prepared from bovine hemoglobin *cannot be used for blood gas analysers not capable fo measuring hemolysate
- Contents/Configuration
- ・frozen liquid
・6 ampouls, 2 ampouls for each of 3 levels (1, 2, 3), each ampouls contains 1.5 mL with an air-tight glass ampoule
- Expiration date
- ・temperature below -70℃~-90℃
・shelf life: 9 months after the date of the receipt (2℃~10℃/4 days in a refrigerator)
- Certificate of Analysis
-
- Certified Reference Material for Ion Selective Electrode(ISE)JCCRM 111 (IP3-3)
Na, K, Cl
- ¥41,000
-
- Specification
- ・Japanese primary reference material for Na, K, Cl for ISE measurement
・Na was assayed by definitive method, K was assayed by Isotope dilution mass spectrometry(ID/MS). Cl was assayed by ion-chromatography and coulometric titration
- Contents/Configuration
- ・frozen liquid
・3 vials, one ampoule for each of 3 levels (L, M, H), each ampoule contains 1.0 mL
・glass ampoule (Do not reuse opened ampule.)
- Expiration date
- ・temperature below -70℃
・shelf life: 9 months after the date of the receipt
・when stored at a temperatures -20℃, expiration is 1 month
- Certificate of Analysis
-
- Trueness Control Material for Ion-Selective ElectrodeJCTCM 130 (JCTCM 130)
Na, K, Cl
- ¥31,000
-
- Specification
- ・Secondary reference material for Na, K, Cl
・Concentration of sodium and potassium were assayed by using flame photometry (Na, K) , chloride was assayed by coulometric titration (Cl)
・Intended to be used for the calibration of routine ISE(Ion Selective Electrode) analyzers measuring Na, K, and Cl in blood serum(blood plasma) using ISE(diluted or undiluted) in clinical testing
- Contents/Configuration
- ・liquid
・30 ampoules, 10 ampoules for each of 3 levels(L, M, H)
・each ampoule contains 1.0 mL
・glass ampoule (Do not reuse opened ampoule.)
- Expiration date
- ・temperature 2℃~8℃ refrigerator, shelf life: 6 months after the date of the receipt
or -20℃ freezer, shelf life: 12 months after the date of the receipt
- Certificate of Analysis
-
- Truness Control Material for Ion-Selective ElectrodeJCTCM 131 (JCTCM 131)
Na, K, Cl
- ¥20,750
-
- Specification
- ・Secondary reference material for Na, K, Cl
・Concentration of sodium and potassium were assayed by using flame photometry (Na, K) , chloride was assayed by coulometric titration (Cl)
・Intended to be used for the calibration of routine ISE(Ion Selective Electrode) analyzers measuring Na, K, and Cl in blood serum(blood plasma) using ISE(diluted or undiluted) in clinical testing
- Contents/Configuration
- ・liquid
・20 ampoules for M level
・each ampoule contains 1.0 mL
・glass ampoule (Do not reuse opened ampoule.)
- Expiration date
- ・temperature 2℃~8℃ refrigerator, shelf life: 6 months after the date of the receipt,
or -20℃ freezer, shelf life: 12 months after the date of the receipt
- Certificate of Analysis
-
- Certified Reference Material for Dialysate MeasurementJCCRM 300 (DIA-300)
pH, pCO2, HCO3-, Na, K, Cl
- ¥49,500
-
- Specification
- ・Reference material for dailysate measurement ( pH, pCO2, HCO3-, Na, K and Cl )
・All items were assayed by IFCC reference method
- Contents/Configuration
- ・liquid
・6 ampoules, 2 ampoules for M and 1 ampoule for H of both Acetic acid and Citric acid, each ampoule contains 3.0 mL with glass ampoule
- Expiration date
- ・temperature 2℃~8℃ in a refrigerator
・shelf life: 2 months after the date of the receipt *avoid frozen
- Certificate of Analysis